- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources4
- Resource Type
-
0002000002000000
- More
- Availability
-
40
- Author / Contributor
- Filter by Author / Creator
-
-
Meinhold, Waiman (4)
-
Ueda, Jun (4)
-
Hu, Ai-Ping (3)
-
Martinez, Daniel Enrique (3)
-
Oshinski, John (3)
-
Kawase, Hiroaki (1)
-
Miles, Toni P (1)
-
Zeagler, Clint (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
- Filter by Editor
-
-
null (3)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Martinez, Daniel Enrique; Meinhold, Waiman; Oshinski, John; Hu, Ai-Ping; Ueda, Jun (, Journal of Medical Robotics Research)null (Ed.)This paper presents the development of a magnetic resonance imaging (MRI)-conditional needle positioning robot designed for spinal cellular injection. High-accuracy targeting performance is achieved by the combination of a high precision, parallel-plane, needle-orientation mechanism utilizing linear piezoelectric actuators with an iterative super-resolution (SR) visual navigation algorithm using multi-planar MR imaging. In previous work, the authors have developed an MRI conditional robot with positioning performance exceeding the standard resolution of MRI, rendering the MRI resolution the limit for navigation. This paper further explores the application of SR to images for robot guidance, evaluating positioning performance through simulations and experimentally in benchtop and MRI experiments.more » « less
-
Meinhold, Waiman; Martinez, Daniel Enrique; Oshinski, John; Hu, Ai-Ping; Ueda, Jun (, IEEE Transactions on Biomedical Engineering)null (Ed.)
-
Martinez, Daniel Enrique; Meinhold, Waiman; Oshinski, John; Hu, Ai-Ping; Ueda, Jun (, 2020 International Symposium on Medical Robotics (ISMR))null (Ed.)
An official website of the United States government
